These steels can be used in a very wide range of applications, both indoors and outdoors. One example is this metallic ceiling for a railway station.
ArcelorMittal's hot dip galvanised steels consist of a steel substrate with a metallic zinc coating applied by means of a continuous hot dip galvanising process. Metallic zinc coatings are available in steel grades ranging from steel for bending and deep drawing applications, to structural steels and high yield strength steels.
A glossy surface finish obtained under specific skin-pass conditions (either non-skin-passed or skin-passed with smooth cylinders to obtain low roughness) can be provided if required at time of enquiry.
Hot dip galvanised products offer excellent corrosion resistance combined with very good forming properties. The coating process can apply very thick zinc layers, up to 725 g/m² (total of both sides).
ArcelorMittal's hot dip galvanised steels can be used in a very wide range of applications for industrial markets, both indoors and outdoors. Some of the most common applications are:
Zinc hot dip galvanised steel is suitable for contact with foodstuffs under certain conditions, as specified in the Regulation (EC) No. 1935/2004 and French standard NF A 36-712-1. Please contact us for further information on this subject.
Storage
Galvanised strips are usually supplied passivated or oiled to temporarily limit any risk of white rust formation. During transport and storage, all necessary precautions must be taken to keep the material dry and to prevent the formation of condensation. Improved protection can be achieved by the application of an Easyfilm® thin organic coating (please see data sheet E80 for the specific properties of Easyfilm®).
Forming and joining
The forming and joining techniques currently used for uncoated steel are also suitable for galvanised steel.
It is essential to select a coating thickness that is compatible with the forming and joining processes envisaged, without compromising the desired degree of corrosion protection.
Painting
Hot dip galvanised steels can be painted after degreasing and surface treatment when supplied oiled. If an Easyfilm® thin organic coating has been applied, they can be painted directly, without any prior surface treatment. However, the paint must be compatible with the Easyfilm® resin.
In electrical resistance welding, the welding current must be suitably regulated and regularly adjusted. Electrode life can be extended by regularly stepping up the welding current and periodically dressing (machining) the electrodes.
Designation EN 10346 | Coating weight - double sided (g/m²) | Coating thickness (µm per side) |
---|---|---|
Z100 | 100 | 7.0 |
Z140 | 140 | 10.0 |
Z200 | 200 | 14.0 |
Z225 | 225 | 16.0 |
Z275 | 275 | 20.0 |
Z350 | 350 | 25.0 |
Z450 | 450 | 31.0 |
Z600 | 600 | 42.0 |
Not included in the standard | ||
Z80 | 80 | 5.5 |
Z725 | 725 | 51.0 |
For other coating weights, please contact us.
ASTM A653 | EN 10346:2009 | EN 10346:2015 | Old brand names | |
---|---|---|---|---|
DX51D +Z EN 10346 | CS | DX51D+Z | DX51D+Z | |
DX52D +Z EN 10346 | FS | DX52D+Z | DX52D+Z | |
DX53D +Z EN 10346 | DDS | DX53D+Z | DX53D+Z | |
DX54D +Z EN 10346 | EDDS | DX54D+Z | DX54D+Z | |
DX56D +Z EN 10346 | DX56D+Z | DX56D+Z | ||
DX57D +Z EN 10346 | DX57D+Z | DX57D+Z |
DX51D +Z EN 10346 | |
---|---|
ASTM A653 | CS |
EN 10346:2009 | DX51D+Z |
EN 10346:2015 | DX51D+Z |
DX52D +Z EN 10346 | |
---|---|
ASTM A653 | FS |
EN 10346:2009 | DX52D+Z |
EN 10346:2015 | DX52D+Z |
DX53D +Z EN 10346 | |
---|---|
ASTM A653 | DDS |
EN 10346:2009 | DX53D+Z |
EN 10346:2015 | DX53D+Z |
DX54D +Z EN 10346 | |
---|---|
ASTM A653 | EDDS |
EN 10346:2009 | DX54D+Z |
EN 10346:2015 | DX54D+Z |
DX56D +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | DX56D+Z |
EN 10346:2015 | DX56D+Z |
DX57D +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | DX57D+Z |
EN 10346:2015 | DX57D+Z |
ASTM A653 | EN 10346:2009 | EN 10346:2015 | Old brand names | |
---|---|---|---|---|
S220GD +Z EN 10346 | CS Type B | S220GD+Z | S220GD+Z | |
S250GD +Z EN 10346 | SS Grade 230 | S250GD+Z | S250GD+Z | |
S280GD +Z EN 10346 | SS Grade 255 | S280GD+Z | S280GD+Z | |
S320GD +Z EN 10346 | SS Grade 275 | S320GD+Z | S320GD+Z | |
S350GD +Z EN 10346 | SS Grade 340 Class 4 | S350GD+Z | S350GD+Z | |
S390GD +Z EN 10346 | S390GD+Z | |||
S420GD +Z EN 10346 | SS Grade 410 | S420GD+Z | ||
S420GD-HyPer® +Z** | ||||
S450GD +Z EN 10346 | S450GD+Z | |||
S450GD-HyPer® +Z** | ||||
S550GD +Z EN 10346 | S550GD+Z | S550GD+Z | ||
S550GD-HyPer® +Z*** |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
S220GD +Z EN 10346 | |
---|---|
ASTM A653 | CS Type B |
EN 10346:2009 | S220GD+Z |
EN 10346:2015 | S220GD+Z |
S250GD +Z EN 10346 | |
---|---|
ASTM A653 | SS Grade 230 |
EN 10346:2009 | S250GD+Z |
EN 10346:2015 | S250GD+Z |
S280GD +Z EN 10346 | |
---|---|
ASTM A653 | SS Grade 255 |
EN 10346:2009 | S280GD+Z |
EN 10346:2015 | S280GD+Z |
S320GD +Z EN 10346 | |
---|---|
ASTM A653 | SS Grade 275 |
EN 10346:2009 | S320GD+Z |
EN 10346:2015 | S320GD+Z |
S350GD +Z EN 10346 | |
---|---|
ASTM A653 | SS Grade 340 Class 4 |
EN 10346:2009 | S350GD+Z |
EN 10346:2015 | S350GD+Z |
S390GD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | |
EN 10346:2015 | S390GD+Z |
S420GD +Z EN 10346 | |
---|---|
ASTM A653 | SS Grade 410 |
EN 10346:2009 | |
EN 10346:2015 | S420GD+Z |
S420GD-HyPer® +Z** | |
---|---|
ASTM A653 | |
EN 10346:2009 | |
EN 10346:2015 | |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
S450GD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | |
EN 10346:2015 | S450GD+Z |
S450GD-HyPer® +Z** | |
---|---|
ASTM A653 | |
EN 10346:2009 | |
EN 10346:2015 | |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
S550GD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | S550GD+Z |
EN 10346:2015 | S550GD+Z |
S550GD-HyPer® +Z*** | |
---|---|
ASTM A653 | |
EN 10346:2009 | |
EN 10346:2015 | |
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
ASTM A653 | EN 10346:2009 | EN 10346:2015 | Old brand names | |
---|---|---|---|---|
HX180YD +Z EN 10346 | HX180YD+Z | HX180YD+Z | ||
HX220YD +Z EN 10346 | HX220YD+Z | HX220YD+Z | ||
HX260YD +Z EN 10346 | HX260YD+Z | HX260YD+Z | ||
HX300YD +Z EN 10346 | HX300YD+Z | HX300YD+Z |
HX180YD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX180YD+Z |
EN 10346:2015 | HX180YD+Z |
HX220YD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX220YD+Z |
EN 10346:2015 | HX220YD+Z |
HX260YD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX260YD+Z |
EN 10346:2015 | HX260YD+Z |
HX300YD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX300YD+Z |
EN 10346:2015 | HX300YD+Z |
ASTM A653 | EN 10346:2009 | EN 10346:2015 | Old brand names | |
---|---|---|---|---|
HX260LAD +Z EN 10346 | HX260LAD+Z | HX260LAD+Z | ||
HX300LAD +Z EN 10346 | HX300LAD+Z | HX300LAD+Z | ||
HX340LAD +Z EN 10346 | HX340LAD+Z | HX340LAD+Z | ||
HX380LAD +Z EN 10346 | HX380LAD+Z | HX380LAD+Z | ||
HX420LAD +Z EN 10346 | HX420LAD+Z | HX420LAD+Z | ||
HX460LAD +Z EN 10346 | HX460LAD+Z | HX460LAD+Z | ||
HX500LAD +Z EN 10346 | HX500LAD+Z | HX500LAD+Z | ||
HX700LAD +Z* |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
HX260LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX260LAD+Z |
EN 10346:2015 | HX260LAD+Z |
HX300LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX300LAD+Z |
EN 10346:2015 | HX300LAD+Z |
HX340LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX340LAD+Z |
EN 10346:2015 | HX340LAD+Z |
HX380LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX380LAD+Z |
EN 10346:2015 | HX380LAD+Z |
HX420LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX420LAD+Z |
EN 10346:2015 | HX420LAD+Z |
HX460LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX460LAD+Z |
EN 10346:2015 | HX460LAD+Z |
HX500LAD +Z EN 10346 | |
---|---|
ASTM A653 | |
EN 10346:2009 | HX500LAD+Z |
EN 10346:2015 | HX500LAD+Z |
HX700LAD +Z* | |
---|---|
ASTM A653 | |
EN 10346:2009 | |
EN 10346:2015 | |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
* Steel grade HX700LAD +Z is not recommended for automotive applications.
Thickness (mm) | Min width | DX51D +Z EN 10346, DX52D +Z EN 10346, DX53D +Z EN 10346, DX54D +Z EN 10346, DX56D +Z EN 10346 | DX57D +Z EN 10346 |
---|---|---|---|
Max width | Max width | ||
0.30 ≤ th < 6.00 | 600 | 2080 | 1840 |
For the detailed feasibility, please contact us.
For the detailed feasibility, please contact us.
Thickness (mm) | Min width | S220GD +Z EN 10346, S250GD +Z EN 10346, S280GD +Z EN 10346, S320GD +Z EN 10346, S350GD +Z EN 10346, S390GD +Z EN 10346, S420GD +Z EN 10346, S420GD-HyPer® +Z**, S450GD +Z EN 10346, S450GD-HyPer® +Z**, S550GD +Z EN 10346, S550GD-HyPer® +Z*** |
---|---|---|
Max width | ||
0.25 ≤ th < 6.00 | 600 | 1650 |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
For the detailed feasibility, please contact us.
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
Thickness (mm) | Min width | Max width |
---|---|---|
0.25 ≤ th < 6.00 | 600 | 1650 |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
For the detailed feasibility, please contact us.
Thickness (mm) | Min width | HX180YD +Z EN 10346, HX220YD +Z EN 10346, HX260YD +Z EN 10346 | HX300YD +Z EN 10346 |
---|---|---|---|
Max width | Max width | ||
0.25 ≤ th < 3.00 | 600 | 2080 | 1750 |
For the detailed feasibility, please contact us.
Thickness (mm) | Min width | Max width |
---|---|---|
0.25 ≤ th < 3.00 | 600 | 2080 |
Thickness (mm) | Min width | Max width |
---|---|---|
0.25 ≤ th < 3.00 | 600 | 2080 |
For the detailed feasibility, please contact us.
Thickness (mm) | Min width | HX260LAD +Z EN 10346 | HX300LAD +Z EN 10346 | HX340LAD +Z EN 10346, HX500LAD +Z EN 10346 | HX380LAD +Z EN 10346 | HX420LAD +Z EN 10346, HX460LAD +Z EN 10346 | HX700LAD +Z* |
---|---|---|---|---|---|---|---|
Max width | Max width | Max width | Max width | Max width | Max width | ||
0.30 ≤ th < 6.00 | 600 | 2080 | 1860 | 1680 | 1840 | 1780 | 1300 |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
For the detailed feasibility, please contact us.
Thickness (mm) | Min width | Max width |
---|---|---|
0.30 ≤ th < 6.00 | 600 | 2080 |
Thickness (mm) | Min width | Max width |
---|---|---|
0.30 ≤ th < 6.00 | 600 | 1860 |
Thickness (mm) | Min width | Max width |
---|---|---|
0.30 ≤ th < 6.00 | 600 | 1680 |
Thickness (mm) | Min width | Max width |
---|---|---|
0.30 ≤ th < 6.00 | 600 | 1840 |
Thickness (mm) | Min width | Max width |
---|---|---|
0.30 ≤ th < 6.00 | 600 | 1780 |
Thickness (mm) | Min width | Max width |
---|---|---|
0.30 ≤ th < 6.00 | 600 | 1780 |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
For the detailed feasibility, please contact us.
Steels for cold forming and deep drawing applications: mechanical properties transverse to the rolling direction
Structural steels: mechanical properties in the rolling direction (longitudinal)
High strength interstitial free steels: mechanical properties transverse to the rolling direction
High Strength Low Alloy steels: mechanical properties transverse to the rolling direction
Notes | Direction | Thickness (mm) | Re (MPa) | Rm (MPa) | A80 (%) | r90 | n90 | |
---|---|---|---|---|---|---|---|---|
DX51D +Z EN 10346 | 1 | T | 0.2 - 0.35 | - | 270 - 500 | ≥ 15 | - | - |
0.35 - 0.5 | ≥ 18 | |||||||
0.5 - 0.7 | ≥ 20 | |||||||
0.7 - 6 | ≥ 22 | |||||||
DX52D +Z EN 10346 | 2+1 | T | 0.3 - 0.5 | 140 - 300 | 270 - 420 | ≥ 22 | - | - |
0.5 - 0.7 | ≥ 24 | |||||||
0.7 - 6 | ≥ 26 | |||||||
DX53D +Z EN 10346 | 1 | T | 0.3 - 0.5 | 140 - 260 | 270 - 380 | ≥ 26 | - | - |
0.5 - 0.7 | ≥ 28 | |||||||
0.7 - 6 | ≥ 30 | |||||||
DX54D +Z EN 10346 | 3 | T | 0.3 - 0.5 | 120 - 220 | 260 - 350 | ≥ 32 | ≥ 1.6 | ≥ 0.180 |
0.5 - 0.7 | ≥ 34 | |||||||
0.7 - 1.5 | ≥ 36 | |||||||
1.5 - 2 | ≥ 1.4 | |||||||
2 - 3 | ≥ 1.2 | |||||||
DX56D +Z EN 10346 | 3 | T | 0.3 - 0.5 | 120 - 180 | 260 - 350 | ≥ 35 | ≥ 1.9 | ≥ 0.210 |
0.5 - 0.7 | ≥ 37 | |||||||
0.7 - 1.5 | ≥ 39 | |||||||
1.5 - 2 | ≥ 1.7 | |||||||
2 - 3 | ≥ 1.5 | |||||||
DX57D +Z EN 10346 | 3 | T | 0.5 - 0.7 | 120 - 170 | 260 - 350 | ≥ 39 | ≥ 2.1 | ≥ 0.220 |
0.7 - 1.5 | ≥ 41 | |||||||
1.5 - 2 | ≥ 1.9 | |||||||
2 - 3 | ≥ 1.7 |
1. Guarantee for mechanical properties ≤ 1 month
2. For DX52D +Z EN 10346 the Re-value only applies to skin-passed products (surface qualities B and C).
3. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | DX51D +Z EN 10346 | |
---|---|---|---|---|
Rm (MPa) | 1 | T | 0.2 - 6 | 270 - 500 |
A80 (%) | T | 0.2 - 0.35 | ≥ 15 | |
0.35 - 0.5 | ≥ 18 | |||
0.5 - 0.7 | ≥ 20 | |||
0.7 - 6 | ≥ 22 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | DX52D +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 2+1 | T | 0.3 - 6 | 140 - 300 |
Rm (MPa) | T | 0.3 - 6 | 270 - 420 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 22 | |
0.5 - 0.7 | ≥ 24 | |||
0.7 - 6 | ≥ 26 |
1. Guarantee for mechanical properties ≤ 1 month
2. For DX52D +Z EN 10346 the Re-value only applies to skin-passed products (surface qualities B and C).
Notes | Direction | Thickness (mm) | DX53D +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.3 - 6 | 140 - 260 |
Rm (MPa) | T | 0.3 - 6 | 270 - 380 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 26 | |
0.5 - 0.7 | ≥ 28 | |||
0.7 - 6 | ≥ 30 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | DX54D +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 3 | T | 0.3 - 3 | 120 - 220 |
Rm (MPa) | T | 0.3 - 3 | 260 - 350 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 32 | |
0.5 - 0.7 | ≥ 34 | |||
0.7 - 3 | ≥ 36 | |||
r90 | T | 0.3 - 1.5 | ≥ 1.6 | |
1.5 - 2 | ≥ 1.4 | |||
2 - 3 | ≥ 1.2 | |||
n90 | T | 0.3 - 3 | ≥ 0.180 |
3. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | DX56D +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 3 | T | 0.3 - 3 | 120 - 180 |
Rm (MPa) | T | 0.3 - 3 | 260 - 350 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 35 | |
0.5 - 0.7 | ≥ 37 | |||
0.7 - 3 | ≥ 39 | |||
r90 | T | 0.3 - 1.5 | ≥ 1.9 | |
1.5 - 2 | ≥ 1.7 | |||
2 - 3 | ≥ 1.5 | |||
n90 | T | 0.3 - 3 | ≥ 0.210 |
3. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | DX57D +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 3 | T | 0.5 - 3 | 120 - 170 |
Rm (MPa) | T | 0.5 - 3 | 260 - 350 | |
A80 (%) | T | 0.5 - 0.7 | ≥ 39 | |
0.7 - 3 | ≥ 41 | |||
r90 | T | 0.5 - 1.5 | ≥ 2.1 | |
1.5 - 2 | ≥ 1.9 | |||
2 - 3 | ≥ 1.7 | |||
n90 | T | 0.5 - 3 | ≥ 0.220 |
3. Guarantee for mechanical properties ≤ 6 months
1. Guarantee for mechanical properties ≤ 1 month
2. For DX52D +Z EN 10346 the Re-value only applies to skin-passed products (surface qualities B and C).
3. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | Re (MPa) | Rm (MPa) | A80 (%) | |
---|---|---|---|---|---|---|
S220GD +Z EN 10346 | 1 | L | 0.25 - 0.35 | ≥ 220 | ≥ 300 | ≥ 13 |
0.35 - 0.5 | ≥ 16 | |||||
0.5 - 0.7 | ≥ 18 | |||||
0.7 - 6 | ≥ 20 | |||||
S250GD +Z EN 10346 | 1 | L | 0.25 - 0.35 | ≥ 250 | ≥ 330 | ≥ 12 |
0.35 - 0.5 | ≥ 15 | |||||
0.5 - 0.7 | ≥ 17 | |||||
0.7 - 6 | ≥ 19 | |||||
S280GD +Z EN 10346 | 1 | L | 0.25 - 0.35 | ≥ 280 | ≥ 360 | ≥ 11 |
0.35 - 0.5 | ≥ 14 | |||||
0.5 - 0.7 | ≥ 16 | |||||
0.7 - 6 | ≥ 18 | |||||
S320GD +Z EN 10346 | 1 | L | 0.25 - 0.35 | ≥ 320 | ≥ 390 | ≥ 10 |
0.35 - 0.5 | ≥ 13 | |||||
0.5 - 0.7 | ≥ 15 | |||||
0.7 - 6 | ≥ 17 | |||||
S350GD +Z EN 10346 | 1 | L | 0.3 - 0.5 | ≥ 350 | ≥ 420 | ≥ 12 |
0.5 - 0.7 | ≥ 14 | |||||
0.7 - 6 | ≥ 16 | |||||
S390GD +Z EN 10346 | 1 | L | 0.35 - 0.5 | ≥ 390 | ≥ 460 | ≥ 12 |
0.5 - 0.7 | ≥ 14 | |||||
0.7 - 6 | ≥ 16 | |||||
S420GD +Z EN 10346 | 1 | L | 0.35 - 0.5 | ≥ 420 | ≥ 480 | ≥ 11 |
0.5 - 0.7 | ≥ 13 | |||||
0.7 - 6 | ≥ 15 | |||||
S420GD-HyPer® +Z** | 2+1 | L | 0.7 - 4 | ≥ 420 | 480 - 620 | ≥ 15 |
S450GD +Z EN 10346 | 1 | L | 0.35 - 0.5 | ≥ 450 | ≥ 510 | ≥ 10 |
0.5 - 0.7 | ≥ 12 | |||||
0.7 - 6 | ≥ 14 | |||||
S450GD-HyPer® +Z** | 2+1 | L | 0.7 - 4 | ≥ 450 | 510 - 650 | ≥ 15 |
S550GD +Z EN 10346 | 1 | L | 0.2 - 3 | ≥ 550 | ≥ 560 | - |
S550GD-HyPer® +Z*** | 2+1 | L | 0.7 - 5 | ≥ 550 | 600 - 760 | ≥ 13 |
5 - 6 | ≥ 14 |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
1. Guarantee for mechanical properties ≤ 1 month
2. Upper limit of Rm for easier piercing and screwing.
Notes | Direction | Thickness (mm) | S220GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.25 - 6 | ≥ 220 |
Rm (MPa) | L | 0.25 - 6 | ≥ 300 | |
A80 (%) | L | 0.25 - 0.35 | ≥ 13 | |
0.35 - 0.5 | ≥ 16 | |||
0.5 - 0.7 | ≥ 18 | |||
0.7 - 6 | ≥ 20 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S250GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.25 - 6 | ≥ 250 |
Rm (MPa) | L | 0.25 - 6 | ≥ 330 | |
A80 (%) | L | 0.25 - 0.35 | ≥ 12 | |
0.35 - 0.5 | ≥ 15 | |||
0.5 - 0.7 | ≥ 17 | |||
0.7 - 6 | ≥ 19 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S280GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.25 - 6 | ≥ 280 |
Rm (MPa) | L | 0.25 - 6 | ≥ 360 | |
A80 (%) | L | 0.25 - 0.35 | ≥ 11 | |
0.35 - 0.5 | ≥ 14 | |||
0.5 - 0.7 | ≥ 16 | |||
0.7 - 6 | ≥ 18 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S320GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.25 - 6 | ≥ 320 |
Rm (MPa) | L | 0.25 - 6 | ≥ 390 | |
A80 (%) | L | 0.25 - 0.35 | ≥ 10 | |
0.35 - 0.5 | ≥ 13 | |||
0.5 - 0.7 | ≥ 15 | |||
0.7 - 6 | ≥ 17 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S350GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.3 - 6 | ≥ 350 |
Rm (MPa) | L | 0.3 - 6 | ≥ 420 | |
A80 (%) | L | 0.3 - 0.5 | ≥ 12 | |
0.5 - 0.7 | ≥ 14 | |||
0.7 - 6 | ≥ 16 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S390GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.35 - 6 | ≥ 390 |
Rm (MPa) | L | 0.35 - 6 | ≥ 460 | |
A80 (%) | L | 0.35 - 0.5 | ≥ 12 | |
0.5 - 0.7 | ≥ 14 | |||
0.7 - 6 | ≥ 16 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S420GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.35 - 6 | ≥ 420 |
Rm (MPa) | L | 0.35 - 6 | ≥ 480 | |
A80 (%) | L | 0.35 - 0.5 | ≥ 11 | |
0.5 - 0.7 | ≥ 13 | |||
0.7 - 6 | ≥ 15 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S420GD-HyPer® +Z** | |
---|---|---|---|---|
Re (MPa) | 2+1 | L | 0.7 - 4 | ≥ 420 |
Rm (MPa) | L | 0.7 - 4 | 480 - 620 | |
A80 (%) | L | 0.7 - 4 | ≥ 15 |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
1. Guarantee for mechanical properties ≤ 1 month
2. Upper limit of Rm for easier piercing and screwing.
Notes | Direction | Thickness (mm) | S450GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.35 - 6 | ≥ 450 |
Rm (MPa) | L | 0.35 - 6 | ≥ 510 | |
A80 (%) | L | 0.35 - 0.5 | ≥ 10 | |
0.5 - 0.7 | ≥ 12 | |||
0.7 - 6 | ≥ 14 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S450GD-HyPer® +Z** | |
---|---|---|---|---|
Re (MPa) | 2+1 | L | 0.7 - 4 | ≥ 450 |
Rm (MPa) | L | 0.7 - 4 | 510 - 650 | |
A80 (%) | L | 0.7 - 4 | ≥ 15 |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
1. Guarantee for mechanical properties ≤ 1 month
2. Upper limit of Rm for easier piercing and screwing.
Notes | Direction | Thickness (mm) | S550GD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | L | 0.2 - 3 | ≥ 550 |
Rm (MPa) | L | 0.2 - 3 | ≥ 560 |
1. Guarantee for mechanical properties ≤ 1 month
Notes | Direction | Thickness (mm) | S550GD-HyPer® +Z*** | |
---|---|---|---|---|
Re (MPa) | 2+1 | L | 0.7 - 6 | ≥ 550 |
Rm (MPa) | L | 0.7 - 6 | 600 - 760 | |
A80 (%) | L | 0.7 - 5 | ≥ 13 | |
5 - 6 | ≥ 14 |
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
1. Guarantee for mechanical properties ≤ 1 month
2. Upper limit of Rm for easier piercing and screwing.
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
1. Guarantee for mechanical properties ≤ 1 month
2. Upper limit of Rm for easier piercing and screwing.
Notes | Direction | Thickness (mm) | Re (MPa) | Rm (MPa) | A80 (%) | r90 | n90 | |
---|---|---|---|---|---|---|---|---|
HX180YD +Z EN 10346 | 1 | T | 0.45 - 0.5 | 180 - 240 | 330 - 390 | ≥ 30 | ≥ 1.3 | ≥ 0.140 |
0.5 - 0.7 | ≥ 32 | ≥ 1.5 | ≥ 0.170 | |||||
0.7 - 3 | ≥ 34 | ≥ 1.7 | ≥ 0.180 | |||||
HX220YD +Z EN 10346 | 1 | T | 0.45 - 0.5 | 220 - 280 | 340 - 420 | ≥ 28 | ≥ 1.1 | ≥ 0.130 |
0.5 - 0.7 | ≥ 30 | ≥ 1.3 | ≥ 0.160 | |||||
0.7 - 3 | ≥ 32 | ≥ 1.5 | ≥ 0.170 | |||||
HX260YD +Z EN 10346 | 1 | T | 0.45 - 0.5 | 260 - 320 | 380 - 440 | ≥ 26 | ≥ 1 | ≥ 0.120 |
0.5 - 0.7 | ≥ 28 | ≥ 1.2 | ≥ 0.150 | |||||
0.7 - 3 | ≥ 30 | ≥ 1.4 | ≥ 0.160 | |||||
HX300YD +Z EN 10346 | 1 | T | 0.45 - 0.5 | 300 - 360 | 390 - 470 | ≥ 23 | ≥ 0.9 | ≥ 0.110 |
0.5 - 0.7 | ≥ 25 | ≥ 1.1 | ≥ 0.140 | |||||
0.7 - 3 | ≥ 27 | ≥ 1.3 | ≥ 0.150 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX180YD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.45 - 3 | 180 - 240 |
Rm (MPa) | T | 0.45 - 3 | 330 - 390 | |
A80 (%) | T | 0.45 - 0.5 | ≥ 30 | |
0.5 - 0.7 | ≥ 32 | |||
0.7 - 3 | ≥ 34 | |||
r90 | T | 0.45 - 0.5 | ≥ 1.3 | |
0.5 - 0.7 | ≥ 1.5 | |||
0.7 - 3 | ≥ 1.7 | |||
n90 | T | 0.45 - 0.5 | ≥ 0.140 | |
0.5 - 0.7 | ≥ 0.170 | |||
0.7 - 3 | ≥ 0.180 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX220YD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.45 - 3 | 220 - 280 |
Rm (MPa) | T | 0.45 - 3 | 340 - 420 | |
A80 (%) | T | 0.45 - 0.5 | ≥ 28 | |
0.5 - 0.7 | ≥ 30 | |||
0.7 - 3 | ≥ 32 | |||
r90 | T | 0.45 - 0.5 | ≥ 1.1 | |
0.5 - 0.7 | ≥ 1.3 | |||
0.7 - 3 | ≥ 1.5 | |||
n90 | T | 0.45 - 0.5 | ≥ 0.130 | |
0.5 - 0.7 | ≥ 0.160 | |||
0.7 - 3 | ≥ 0.170 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX260YD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.45 - 3 | 260 - 320 |
Rm (MPa) | T | 0.45 - 3 | 380 - 440 | |
A80 (%) | T | 0.45 - 0.5 | ≥ 26 | |
0.5 - 0.7 | ≥ 28 | |||
0.7 - 3 | ≥ 30 | |||
r90 | T | 0.45 - 0.5 | ≥ 1 | |
0.5 - 0.7 | ≥ 1.2 | |||
0.7 - 3 | ≥ 1.4 | |||
n90 | T | 0.45 - 0.5 | ≥ 0.120 | |
0.5 - 0.7 | ≥ 0.150 | |||
0.7 - 3 | ≥ 0.160 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX300YD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.45 - 3 | 300 - 360 |
Rm (MPa) | T | 0.45 - 3 | 390 - 470 | |
A80 (%) | T | 0.45 - 0.5 | ≥ 23 | |
0.5 - 0.7 | ≥ 25 | |||
0.7 - 3 | ≥ 27 | |||
r90 | T | 0.45 - 0.5 | ≥ 0.9 | |
0.5 - 0.7 | ≥ 1.1 | |||
0.7 - 3 | ≥ 1.3 | |||
n90 | T | 0.45 - 0.5 | ≥ 0.110 | |
0.5 - 0.7 | ≥ 0.140 | |||
0.7 - 3 | ≥ 0.150 |
1. Guarantee for mechanical properties ≤ 6 months
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | Re (MPa) | Rm (MPa) | A80 (%) | |
---|---|---|---|---|---|---|
HX260LAD +Z EN 10346 | 1 | T | 0.3 - 0.5 | 260 - 330 | 350 - 430 | ≥ 22 |
0.5 - 0.7 | ≥ 24 | |||||
0.7 - 6 | ≥ 26 | |||||
HX300LAD +Z EN 10346 | 1 | T | 0.3 - 0.5 | 300 - 380 | 380 - 480 | ≥ 19 |
0.5 - 0.7 | ≥ 21 | |||||
0.7 - 6 | ≥ 23 | |||||
HX340LAD +Z EN 10346 | 1 | T | 0.3 - 0.5 | 340 - 420 | 410 - 510 | ≥ 17 |
0.5 - 0.7 | ≥ 19 | |||||
0.7 - 6 | ≥ 21 | |||||
HX380LAD +Z EN 10346 | 1 | T | 0.3 - 0.5 | 380 - 480 | 440 - 560 | ≥ 15 |
0.5 - 0.7 | ≥ 17 | |||||
0.7 - 6 | ≥ 19 | |||||
HX420LAD +Z EN 10346 | 1 | T | 0.3 - 0.5 | 420 - 520 | 470 - 590 | ≥ 13 |
0.5 - 0.7 | ≥ 15 | |||||
0.7 - 6 | ≥ 17 | |||||
HX460LAD +Z EN 10346 | 1 | T | 0.4 - 0.5 | 460 - 560 | 500 - 640 | ≥ 11 |
0.5 - 0.7 | ≥ 13 | |||||
0.7 - 6 | ≥ 15 | |||||
HX500LAD +Z EN 10346 | 1 | T | 1.5 - 6 | 500 - 620 | 530 - 690 | ≥ 13 |
HX700LAD +Z* | 1 | T | 2 - 3 | 700 - 840 | 750 - 950 | ≥ 10 |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX260LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.3 - 6 | 260 - 330 |
Rm (MPa) | T | 0.3 - 6 | 350 - 430 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 22 | |
0.5 - 0.7 | ≥ 24 | |||
0.7 - 6 | ≥ 26 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX300LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.3 - 6 | 300 - 380 |
Rm (MPa) | T | 0.3 - 6 | 380 - 480 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 19 | |
0.5 - 0.7 | ≥ 21 | |||
0.7 - 6 | ≥ 23 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX340LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.3 - 6 | 340 - 420 |
Rm (MPa) | T | 0.3 - 6 | 410 - 510 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 17 | |
0.5 - 0.7 | ≥ 19 | |||
0.7 - 6 | ≥ 21 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX380LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.3 - 6 | 380 - 480 |
Rm (MPa) | T | 0.3 - 6 | 440 - 560 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 15 | |
0.5 - 0.7 | ≥ 17 | |||
0.7 - 6 | ≥ 19 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX420LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.3 - 6 | 420 - 520 |
Rm (MPa) | T | 0.3 - 6 | 470 - 590 | |
A80 (%) | T | 0.3 - 0.5 | ≥ 13 | |
0.5 - 0.7 | ≥ 15 | |||
0.7 - 6 | ≥ 17 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX460LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 0.4 - 6 | 460 - 560 |
Rm (MPa) | T | 0.4 - 6 | 500 - 640 | |
A80 (%) | T | 0.4 - 0.5 | ≥ 11 | |
0.5 - 0.7 | ≥ 13 | |||
0.7 - 6 | ≥ 15 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX500LAD +Z EN 10346 | |
---|---|---|---|---|
Re (MPa) | 1 | T | 1.5 - 6 | 500 - 620 |
Rm (MPa) | T | 1.5 - 6 | 530 - 690 | |
A80 (%) | T | 1.5 - 6 | ≥ 13 |
1. Guarantee for mechanical properties ≤ 6 months
Notes | Direction | Thickness (mm) | HX700LAD +Z* | |
---|---|---|---|---|
Re (MPa) | 1 | T | 2 - 3 | 700 - 840 |
Rm (MPa) | T | 2 - 3 | 750 - 950 | |
A80 (%) | T | 2 - 3 | ≥ 10 |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
1. Guarantee for mechanical properties ≤ 6 months
* Steel grade HX700LAD +Z is not recommended for automotive applications.
1. Guarantee for mechanical properties ≤ 6 months
C (%) | Mn (%) | P (%) | S (%) | Si (%) | Ti (%) | |
---|---|---|---|---|---|---|
DX51D +Z EN 10346 | ≤ 0.180 | ≤ 1.20 | ≤ 0.120 | ≤ 0.045 | ≤ 0.50 | ≤ 0.300 |
DX52D +Z EN 10346 | ≤ 0.120 | ≤ 0.60 | ≤ 0.100 | ≤ 0.045 | ≤ 0.50 | ≤ 0.300 |
DX53D +Z EN 10346 | ≤ 0.120 | ≤ 0.60 | ≤ 0.100 | ≤ 0.045 | ≤ 0.50 | ≤ 0.300 |
DX54D +Z EN 10346 | ≤ 0.120 | ≤ 0.60 | ≤ 0.100 | ≤ 0.045 | ≤ 0.50 | ≤ 0.300 |
DX56D +Z EN 10346 | ≤ 0.120 | ≤ 0.60 | ≤ 0.100 | ≤ 0.045 | ≤ 0.50 | ≤ 0.300 |
DX57D +Z EN 10346 | ≤ 0.120 | ≤ 0.60 | ≤ 0.100 | ≤ 0.045 | ≤ 0.50 | ≤ 0.300 |
Notes | DX51D +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.180 | |
Mn (%) | ≤ 1.20 | |
P (%) | ≤ 0.120 | |
S (%) | ≤ 0.045 | |
Si (%) | ≤ 0.50 | |
Ti (%) | ≤ 0.300 | |
Notes | DX52D +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 0.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.045 | |
Si (%) | ≤ 0.50 | |
Ti (%) | ≤ 0.300 | |
Notes | DX53D +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 0.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.045 | |
Si (%) | ≤ 0.50 | |
Ti (%) | ≤ 0.300 | |
Notes | DX54D +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 0.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.045 | |
Si (%) | ≤ 0.50 | |
Ti (%) | ≤ 0.300 | |
Notes | DX56D +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 0.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.045 | |
Si (%) | ≤ 0.50 | |
Ti (%) | ≤ 0.300 | |
Notes | DX57D +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 0.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.045 | |
Si (%) | ≤ 0.50 | |
Ti (%) | ≤ 0.300 | |
Notes | C (%) | Mn (%) | P (%) | S (%) | Si (%) | |
---|---|---|---|---|---|---|
S220GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S250GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S280GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S320GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S350GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S390GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S420GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S420GD-HyPer® +Z** | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S450GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S450GD-HyPer® +Z** | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S550GD +Z EN 10346 | 1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
S550GD-HyPer® +Z*** | 2+1 | ≤ 0.200 | ≤ 1.70 | ≤ 0.100 | ≤ 0.045 | ≤ 0.60 |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
2. Nb ≤ 0.100% and Ti ≤ 0.08%
Notes | S220GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S250GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S280GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S320GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S350GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S390GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S420GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S420GD-HyPer® +Z** | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S450GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S450GD-HyPer® +Z** | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
** Steel grade with Rm/Re > 1.1 in accordance with the requirements of Eurocode 3 (EN 1993-1-1)
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S550GD +Z EN 10346 | |
---|---|---|
C (%) | 1 | ≤ 0.200 |
Mn (%) | 1 | ≤ 1.70 |
P (%) | 1 | ≤ 0.100 |
S (%) | 1 | ≤ 0.045 |
Si (%) | 1 | ≤ 0.60 |
Al (%) | 1 | - |
Cu (%) | 1 | - |
Cr (%) | 1 | - |
Ni (%) | 1 | - |
Nb (%) | 1 | - |
V (%) | 1 | - |
Ti (%) | 1 | - |
B (%) | 1 | - |
N (%) | 1 | - |
Ceq (%) | 1 | - |
PCM (%) | 1 | - |
1. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
Notes | S550GD-HyPer® +Z*** | |
---|---|---|
C (%) | 1+2 | ≤ 0.200 |
Mn (%) | 1+2 | ≤ 1.70 |
P (%) | 1+2 | ≤ 0.100 |
S (%) | 1+2 | ≤ 0.045 |
Si (%) | 1+2 | ≤ 0.60 |
Al (%) | 1+2 | - |
Cu (%) | 1+2 | - |
Cr (%) | 1+2 | - |
Ni (%) | 1+2 | - |
Nb (%) | 1+2 | - |
V (%) | 1+2 | - |
Ti (%) | 1+2 | - |
B (%) | 1+2 | - |
N (%) | 1+2 | - |
Ceq (%) | 1+2 | - |
PCM (%) | 1+2 | - |
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
1. Nb ≤ 0.100% and Ti ≤ 0.08%
2. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
*** Steel grade with Rm/Re > 1.05 in accordance with the requirements of Eurocode 3 (EN 1993-1-12)
1. Nb ≤ 0.100% and Ti ≤ 0.08%
2. If, by agreement at the time of enquiry and order, other chemical elements are added, they shall be mentioned on the inspection document which may need a change of classification.
C (%) | Mn (%) | P (%) | S (%) | Si (%) | Al (%) | Nb (%) | Ti (%) | |
---|---|---|---|---|---|---|---|---|
HX180YD +Z EN 10346 | ≤ 0.010 | ≤ 0.70 | ≤ 0.060 | ≤ 0.025 | ≤ 0.30 | ≥ 0.010 | ≤ 0.090 | ≤ 0.120 |
HX220YD +Z EN 10346 | ≤ 0.010 | ≤ 0.90 | ≤ 0.080 | ≤ 0.025 | ≤ 0.30 | ≥ 0.010 | ≤ 0.090 | ≤ 0.120 |
HX260YD +Z EN 10346 | ≤ 0.010 | ≤ 1.60 | ≤ 0.100 | ≤ 0.025 | ≤ 0.30 | ≥ 0.010 | ≤ 0.090 | ≤ 0.120 |
HX300YD +Z EN 10346 | ≤ 0.015 | ≤ 1.60 | ≤ 0.100 | ≤ 0.025 | ≤ 0.30 | ≥ 0.010 | ≤ 0.090 | ≤ 0.120 |
Notes | HX180YD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.010 | |
Mn (%) | ≤ 0.70 | |
P (%) | ≤ 0.060 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.30 | |
Al (%) | ≥ 0.010 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.120 | |
Notes | HX220YD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.010 | |
Mn (%) | ≤ 0.90 | |
P (%) | ≤ 0.080 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.30 | |
Al (%) | ≥ 0.010 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.120 | |
Notes | HX260YD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.010 | |
Mn (%) | ≤ 1.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.30 | |
Al (%) | ≥ 0.010 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.120 | |
Notes | HX300YD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.015 | |
Mn (%) | ≤ 1.60 | |
P (%) | ≤ 0.100 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.30 | |
Al (%) | ≥ 0.010 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.120 | |
C (%) | Mn (%) | P (%) | S (%) | Si (%) | Al (%) | Nb (%) | Ti (%) | |
---|---|---|---|---|---|---|---|---|
HX260LAD +Z EN 10346 | ≤ 0.110 | ≤ 1.00 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.090 | ≤ 0.150 |
HX300LAD +Z EN 10346 | ≤ 0.120 | ≤ 1.40 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.090 | ≤ 0.150 |
HX340LAD +Z EN 10346 | ≤ 0.120 | ≤ 1.40 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.100 | ≤ 0.150 |
HX380LAD +Z EN 10346 | ≤ 0.120 | ≤ 1.50 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.100 | ≤ 0.150 |
HX420LAD +Z EN 10346 | ≤ 0.120 | ≤ 1.60 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.100 | ≤ 0.150 |
HX460LAD +Z EN 10346 | ≤ 0.150 | ≤ 1.70 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.100 | ≤ 0.150 |
HX500LAD +Z EN 10346 | ≤ 0.150 | ≤ 1.70 | ≤ 0.030 | ≤ 0.025 | ≤ 0.50 | ≥ 0.015 | ≤ 0.100 | ≤ 0.150 |
HX700LAD +Z* | ≤ 0.100 | ≤ 2.10 | ≤ 0.025 | ≤ 0.010 | ≤ 0.35 | ≥ 0.020 | ≤ 0.090 | ≤ 0.150 |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
Notes | HX260LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.110 | |
Mn (%) | ≤ 1.00 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.150 | |
Notes | HX300LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 1.40 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.150 | |
Notes | HX340LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 1.40 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.100 | |
Ti (%) | ≤ 0.150 | |
Notes | HX380LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 1.50 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.100 | |
Ti (%) | ≤ 0.150 | |
Notes | HX420LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.120 | |
Mn (%) | ≤ 1.60 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.100 | |
Ti (%) | ≤ 0.150 | |
Notes | HX460LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.150 | |
Mn (%) | ≤ 1.70 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.100 | |
Ti (%) | ≤ 0.150 | |
Notes | HX500LAD +Z EN 10346 | |
---|---|---|
C (%) | ≤ 0.150 | |
Mn (%) | ≤ 1.70 | |
P (%) | ≤ 0.030 | |
S (%) | ≤ 0.025 | |
Si (%) | ≤ 0.50 | |
Al (%) | ≥ 0.015 | |
Nb (%) | ≤ 0.100 | |
Ti (%) | ≤ 0.150 | |
Notes | HX700LAD +Z* | |
---|---|---|
C (%) | ≤ 0.100 | |
Mn (%) | ≤ 2.10 | |
P (%) | ≤ 0.025 | |
S (%) | ≤ 0.010 | |
Si (%) | ≤ 0.35 | |
Al (%) | ≥ 0.020 | |
Nb (%) | ≤ 0.090 | |
Ti (%) | ≤ 0.150 | |
* Steel grade HX700LAD +Z is not recommended for automotive applications.
* Steel grade HX700LAD +Z is not recommended for automotive applications.
Any questions?
Ask them via our contact form on
https://industry.arcelormittal.com/getintouch
All details provided in the ArcelorMittal Flat Carbon Europe S.A. catalogue are for information purposes only. ArcelorMittal Flat Carbon Europe S.A. reserves the right to change its product range at any time without prior notice.