D30 - Semi-processed standard grades
These steels are designed for domestic appliances (e.g. washing machine motors), small industrial motors, fans and this electric drill.
Last update: 2022-04-07
Download
Available grades:
Thickness 0.50 mm
Thickness 0.65 mm
Thickness 0.70 mm
Thickness 0.80 mm
Thickness 1.00 mm
Properties
Semi-processed standard grades have guaranteed magnetic properties in accordance with EN 10341:2006 (which superseded EN 10126:1995 for non-alloyed grades and EN 10165:1995 for alloyed grades). The magnetic properties are developed during the final annealing cycle, which is performed by the client after punching the laminations. This annealing treatment reduces losses and improves permeability and polarisation, as a result of recrystallisation, grain growth and also - for certain grades - decarburisation.
Advantages
The punchability of the semi-processed grades has been optimised by the application of an optimised final skin-pass reduction, after the cold rolling and annealing process. Skin-passing produces a controlled surface roughness, ensuring good material behaviour in the punching presses. This roughness also prevents the strips from sticking during the client’s final annealing treatment. Regarding magnetic performance, skin-passing also plays an important role by stimulating grain growth during the annealing cycle, which results in further reduction of losses and increased permeability of the steel.
Applications
Non-alloyed semi-processed electrical steels are designed for small industrial motors, fans and domestic appliances such as washing machine motors, microwave oven transformers and refrigerator compressors.
Alloyed semi-processed electrical steels are designed for similar higher efficiency versions of these applications, as they have lower losses whilst the permeability remains at a good level.
Recommendations for use
The punching process needs to be carried out with an appropriate lubricant, which must be selected carefully, especially in the case of the alloyed semi-processed grades.
Brand correspondence
Thickness 0.50 mm
Full table
|
EN 10341:2006 |
EN 10126:1995 |
EN 10165:1995 |
IEC/CEI 60404-8-3:2005 |
Old brand names |
M 340-50 K |
M 340-50 K |
|
M 340-50 E |
M 340-50 K5 |
|
M 390-50 K |
M 390-50 K |
|
M 390-50 E |
M 390-50 K5 |
|
M 450-50 K |
M 450-50 K |
|
M 450-50 E |
M 450-50 K5 |
|
M 560-50 K |
M 560-50 K |
|
M 560-50 E |
M 560-50 K5 |
|
M 660-50 K |
M 660-50 K |
M 660-50 D |
|
M 660-50 K5 |
|
M 890-50 K |
M 890-50 K |
M 890-50 D |
|
M 890-50 K5 |
|
M 1050-50 K |
M 1050-50 K |
M 1050-50 D |
|
M 1050-50 K5 |
|
M 340-50 K
|
M 340-50 K |
EN 10341:2006 |
M 340-50 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 340-50 E |
IEC/CEI 60404-8-3:2005 |
M 340-50 K5 |
M 390-50 K
|
M 390-50 K |
EN 10341:2006 |
M 390-50 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 390-50 E |
IEC/CEI 60404-8-3:2005 |
M 390-50 K5 |
M 450-50 K
|
M 450-50 K |
EN 10341:2006 |
M 450-50 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 450-50 E |
IEC/CEI 60404-8-3:2005 |
M 450-50 K5 |
M 560-50 K
|
M 560-50 K |
EN 10341:2006 |
M 560-50 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 560-50 E |
IEC/CEI 60404-8-3:2005 |
M 560-50 K5 |
M 660-50 K
|
M 660-50 K |
EN 10341:2006 |
M 660-50 K |
EN 10126:1995 |
M 660-50 D |
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
M 660-50 K5 |
M 890-50 K
|
M 890-50 K |
EN 10341:2006 |
M 890-50 K |
EN 10126:1995 |
M 890-50 D |
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
M 890-50 K5 |
M 1050-50 K
|
M 1050-50 K |
EN 10341:2006 |
M 1050-50 K |
EN 10126:1995 |
M 1050-50 D |
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
M 1050-50 K5 |
Prev grade
Next grade
Thickness 0.65 mm
Full table
|
EN 10341:2006 |
EN 10126:1995 |
EN 10165:1995 |
IEC/CEI 60404-8-3:2005 |
Old brand names |
M 390-65 K |
M 390-65 K |
|
M 390-65 E |
M 390-65 K5 |
|
M 450-65 K |
M 450-65 K |
|
M 450-65 E |
M 450-65 K5 |
|
M 520-65 K |
M 520-65 K |
|
M 520-65 E |
M 520-65 K5 |
|
M 630-65 K |
M 630-65 K |
|
M 630-50 E |
M 630-65 K5 |
|
M 800-65 K |
M 800-65 K |
M 800-65 D |
|
M 800-65 K5 |
|
M 1000-65 K |
M 1000-65 K |
M 1000-65 D |
|
M 1000-65 K5 |
|
M 1200-65 K |
M 1200-65 K |
M 1200-65 D |
|
M 1200-65 K5 |
|
M 390-65 K
|
M 390-65 K |
EN 10341:2006 |
M 390-65 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 390-65 E |
IEC/CEI 60404-8-3:2005 |
M 390-65 K5 |
M 450-65 K
|
M 450-65 K |
EN 10341:2006 |
M 450-65 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 450-65 E |
IEC/CEI 60404-8-3:2005 |
M 450-65 K5 |
M 520-65 K
|
M 520-65 K |
EN 10341:2006 |
M 520-65 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 520-65 E |
IEC/CEI 60404-8-3:2005 |
M 520-65 K5 |
M 630-65 K
|
M 630-65 K |
EN 10341:2006 |
M 630-65 K |
EN 10126:1995 |
|
EN 10165:1995 |
M 630-50 E |
IEC/CEI 60404-8-3:2005 |
M 630-65 K5 |
M 800-65 K
|
M 800-65 K |
EN 10341:2006 |
M 800-65 K |
EN 10126:1995 |
M 800-65 D |
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
M 800-65 K5 |
M 1000-65 K
|
M 1000-65 K |
EN 10341:2006 |
M 1000-65 K |
EN 10126:1995 |
M 1000-65 D |
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
M 1000-65 K5 |
M 1200-65 K
|
M 1200-65 K |
EN 10341:2006 |
M 1200-65 K |
EN 10126:1995 |
M 1200-65 D |
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
M 1200-65 K5 |
Prev grade
Next grade
Thickness 0.70 mm
Full table
|
EN 10341:2006 |
EN 10126:1995 |
EN 10165:1995 |
IEC/CEI 60404-8-3:2005 |
Old brand names |
M 1000-70 K AM FCE |
|
|
|
|
|
M 1000-70 K AM FCE
|
M 1000-70 K AM FCE |
EN 10341:2006 |
|
EN 10126:1995 |
|
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
|
Prev grade
Next grade
Thickness 0.80 mm
Full table
|
EN 10341:2006 |
EN 10126:1995 |
EN 10165:1995 |
IEC/CEI 60404-8-3:2005 |
Old brand names |
M 1200-80 K AM FCE |
|
|
|
|
|
M 1200-80 K AM FCE
|
M 1200-80 K AM FCE |
EN 10341:2006 |
|
EN 10126:1995 |
|
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
|
Prev grade
Next grade
Thickness 1.00 mm
Full table
|
EN 10341:2006 |
EN 10126:1995 |
EN 10165:1995 |
IEC/CEI 60404-8-3:2005 |
Old brand names |
M 1300-100 K AM FCE |
|
|
|
|
|
M 1800-100 K AM FCE |
|
|
|
|
|
M 1300-100 K AM FCE
|
M 1300-100 K AM FCE |
EN 10341:2006 |
|
EN 10126:1995 |
|
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
|
M 1800-100 K AM FCE
|
M 1800-100 K AM FCE |
EN 10341:2006 |
|
EN 10126:1995 |
|
EN 10165:1995 |
|
IEC/CEI 60404-8-3:2005 |
|
Prev grade
Next grade
Dimensions
Please contact us for thicknesses < 0.50 mm.
Thickness 0.50 mm
Full table
|
Notes |
Side trimmed |
Slit coils |
Min width |
Max width |
Min width |
Max width |
M 340-50 K |
1 |
600 |
1300 |
40 |
600 |
M 390-50 K |
|
M 450-50 K |
|
1350 |
M 560-50 K |
|
M 660-50 K |
|
1400 |
M 890-50 K |
|
M 1050-50 K |
|
M 340-50 K
Notes |
1 |
Side trimmed |
Min width |
600 |
Max width |
1300 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 390-50 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1300 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 450-50 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1350 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 560-50 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1350 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 660-50 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 890-50 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 1050-50 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
Prev grade
Next grade
Thickness 0.65 mm
Full table
|
Notes |
Side trimmed |
Slit coils |
Min width |
Max width |
Min width |
Max width |
M 390-65 K |
1 |
600 |
1300 |
40 |
600 |
M 450-65 K |
|
M 520-65 K |
|
1350 |
M 630-65 K |
|
M 800-65 K |
|
1400 |
M 1000-65 K |
|
M 1200-65 K |
|
M 390-65 K
Notes |
1 |
Side trimmed |
Min width |
600 |
Max width |
1300 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 450-65 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1300 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 520-65 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1350 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 630-65 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1350 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 800-65 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 1000-65 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 1200-65 K
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
Prev grade
Next grade
Thickness 0.70 mm
Full table
|
Side trimmed |
Slit coils |
Min width |
Max width |
Min width |
Max width |
M 1000-70 K AM FCE |
600 |
1400 |
40 |
600 |
M 1000-70 K AM FCE
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
Prev grade
Next grade
Thickness 0.80 mm
Full table
|
Side trimmed |
Slit coils |
Min width |
Max width |
Min width |
Max width |
M 1200-80 K AM FCE |
600 |
1400 |
40 |
600 |
M 1200-80 K AM FCE
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
Prev grade
Next grade
Thickness 1.00 mm
Full table
|
Side trimmed |
Slit coils |
Min width |
Max width |
Min width |
Max width |
M 1300-100 K AM FCE |
600 |
1400 |
40 |
600 |
M 1800-100 K AM FCE |
M 1300-100 K AM FCE
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
M 1800-100 K AM FCE
Notes |
|
Side trimmed |
Min width |
600 |
Max width |
1400 |
Slit coils |
Min width |
40 |
Max width |
600 |
Prev grade
Next grade
Magnetic properties
Thickness 0.50 mm
Full table
|
Conventional density (kg/dm³) |
Max loss (W/kg) at 50 Hz at 1 T |
Max loss (W/kg) at 50 Hz at 1.5 T |
Max loss (W/kg) at 60 Hz at 1.5 T |
Min polarisation (T) at 2500 A/m |
Min polarisation (T) at 5000 A/m |
Min polarisation (T) at 10,000 A/m |
|
Indicative |
Guaranteed |
Indicative |
Guaranteed |
Guaranteed |
Guaranteed |
M 340-50 K |
7.65 |
1.42 |
3.40 |
4.32 |
1.54 |
1.62 |
1.72 |
M 390-50 K |
7.70 |
1.62 |
3.90 |
4.97 |
1.56 |
1.64 |
1.74 |
M 450-50 K |
7.75 |
1.92 |
4.50 |
5.67 |
1.57 |
1.65 |
1.75 |
M 560-50 K |
7.80 |
2.42 |
5.60 |
7.03 |
1.58 |
1.66 |
1.76 |
M 660-50 K |
7.85 |
2.80 |
6.60 |
8.38 |
1.62 |
1.70 |
1.79 |
M 890-50 K |
3.70 |
8.90 |
11.30 |
1.60 |
1.68 |
1.78 |
M 1050-50 K |
4.30 |
10.50 |
13.34 |
1.57 |
1.65 |
1.77 |
M 340-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.65 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
1.42 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
3.40 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
4.32 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.54 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.62 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.72 |
M 390-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.70 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
1.62 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
3.90 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
4.97 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.56 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.64 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.74 |
M 450-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.75 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
1.92 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
4.50 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
5.67 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.57 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.65 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.75 |
M 560-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.80 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
2.42 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
5.60 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
7.03 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.58 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.66 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.76 |
M 660-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
2.80 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
6.60 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
8.38 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.62 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.70 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.79 |
M 890-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
3.70 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
8.90 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
11.30 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.60 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.68 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.78 |
M 1050-50 K
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
4.30 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
10.50 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
13.34 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.57 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.65 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.77 |
Prev grade
Next grade
Thickness 0.65 mm
Full table
|
Conventional density (kg/dm³) |
Max loss (W/kg) at 50 Hz at 1 T |
Max loss (W/kg) at 50 Hz at 1.5 T |
Max loss (W/kg) at 60 Hz at 1.5 T |
Min polarisation (T) at 2500 A/m |
Min polarisation (T) at 5000 A/m |
Min polarisation (T) at 10,000 A/m |
|
Indicative |
Guaranteed |
Indicative |
Guaranteed |
Guaranteed |
Guaranteed |
M 390-65 K |
7.65 |
1.62 |
3.90 |
5.07 |
1.54 |
1.62 |
1.72 |
M 450-65 K |
7.70 |
1.92 |
4.50 |
5.86 |
1.56 |
1.64 |
1.74 |
M 520-65 K |
7.75 |
2.22 |
5.20 |
6.72 |
1.57 |
1.65 |
1.75 |
M 630-65 K |
7.80 |
2.72 |
6.30 |
8.00 |
1.58 |
1.66 |
1.76 |
M 800-65 K |
7.85 |
3.30 |
8.00 |
10.16 |
1.62 |
1.70 |
1.79 |
M 1000-65 K |
4.20 |
10.00 |
12.70 |
1.60 |
1.68 |
1.78 |
M 1200-65 K |
5.00 |
12.00 |
15.24 |
1.57 |
1.65 |
1.77 |
M 390-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.65 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
1.62 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
3.90 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
5.07 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.54 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.62 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.72 |
M 450-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.70 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
1.92 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
4.50 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
5.86 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.56 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.64 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.74 |
M 520-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.75 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
2.22 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
5.20 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
6.72 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.57 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.65 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.75 |
M 630-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.80 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
2.72 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
6.30 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
8.00 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.58 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.66 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.76 |
M 800-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
3.30 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
8.00 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
10.16 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.62 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.70 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.79 |
M 1000-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
4.20 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
10.00 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
12.70 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.60 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.68 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.78 |
M 1200-65 K
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
5.00 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
12.00 |
Max loss (W/kg) at 60 Hz at 1.5 T |
Indicative |
15.24 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.57 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.65 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.77 |
Prev grade
Next grade
Thickness 0.70 mm
Full table
|
Conventional density (kg/dm³) |
Max loss (W/kg) at 50 Hz at 1 T |
Min polarisation (T) at 2500 A/m |
Min polarisation (T) at 5000 A/m |
Min polarisation (T) at 10,000 A/m |
|
Indicative |
Guaranteed |
Guaranteed |
Guaranteed |
M 1000-70 K AM FCE |
7.85 |
4.20 |
1.60 |
1.70 |
1.80 |
M 1000-70 K AM FCE
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
4.20 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
10.00 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.60 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.70 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.80 |
Prev grade
Next grade
Thickness 0.80 mm
Full table
|
Conventional density (kg/dm³) |
Max loss (W/kg) at 50 Hz at 1 T |
Max loss (W/kg) at 50 Hz at 1.5 T |
Min polarisation (T) at 2500 A/m |
Min polarisation (T) at 5000 A/m |
Min polarisation (T) at 10,000 A/m |
|
Indicative |
Guaranteed |
Guaranteed |
Guaranteed |
Guaranteed |
M 1200-80 K AM FCE |
7.85 |
5.00 |
12.00 |
1.60 |
1.70 |
1.80 |
M 1200-80 K AM FCE
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
5.00 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
12.00 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.60 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.70 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.80 |
Prev grade
Next grade
Thickness 1.00 mm
Full table
|
Conventional density (kg/dm³) |
Max loss (W/kg) at 50 Hz at 1 T |
Max loss (W/kg) at 50 Hz at 1.5 T |
Min polarisation (T) at 2500 A/m |
Min polarisation (T) at 5000 A/m |
Min polarisation (T) at 10,000 A/m |
|
Indicative |
Guaranteed |
Guaranteed |
Guaranteed |
Guaranteed |
M 1300-100 K AM FCE |
7.85 |
5.40 |
13.00 |
1.60 |
1.70 |
1.80 |
M 1800-100 K AM FCE |
6.00 |
18.00 |
1.58 |
1.68 |
1.77 |
M 1300-100 K AM FCE
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
5.40 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
13.00 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.60 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.70 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.80 |
M 1800-100 K AM FCE
|
|
|
Conventional density (kg/dm³) |
|
7.85 |
Max loss (W/kg) at 50 Hz at 1 T |
Indicative |
6.00 |
Max loss (W/kg) at 50 Hz at 1.5 T |
Guaranteed |
18.00 |
Min polarisation (T) at 2500 A/m |
Guaranteed |
1.58 |
Min polarisation (T) at 5000 A/m |
Guaranteed |
1.68 |
Min polarisation (T) at 10,000 A/m |
Guaranteed |
1.77 |
Prev grade
Next grade
Mechanical properties
The mechanical properties are for information purposes only.
Thickness 0.50 mm
Full table
|
Direction |
Re (MPa) |
Rm (MPa) |
A80 (%) |
HV |
M 340-50 K |
T |
400 - 450 |
450 - 550 |
7 - 23 |
150 - 210 |
M 390-50 K |
T |
390 - 485 |
445 - 515 |
7 - 26 |
150 - 210 |
M 450-50 K |
T |
355 - 435 |
405 - 475 |
10 - 29 |
135 - 190 |
M 560-50 K |
T |
380 - 440 |
435 - 495 |
10 - 29 |
130 - 185 |
M 660-50 K |
T |
350 - 450 |
380 - 470 |
13 - 30 |
125 - 170 |
M 890-50 K |
T |
285 - 450 |
350 - 470 |
16 - 35 |
120 - 170 |
M 1050-50 K |
T |
240 - 450 |
295 - 470 |
21 - 39 |
105 - 170 |
M 340-50 K
|
Direction |
M 340-50 K |
Re (MPa) |
T |
400 - 450 |
Rm (MPa) |
T |
450 - 550 |
A80 (%) |
T |
7 - 23 |
HV |
T |
150 - 210 |
M 390-50 K
|
Direction |
M 390-50 K |
Re (MPa) |
T |
390 - 485 |
Rm (MPa) |
T |
445 - 515 |
A80 (%) |
T |
7 - 26 |
HV |
T |
150 - 210 |
M 450-50 K
|
Direction |
M 450-50 K |
Re (MPa) |
T |
355 - 435 |
Rm (MPa) |
T |
405 - 475 |
A80 (%) |
T |
10 - 29 |
HV |
T |
135 - 190 |
M 560-50 K
|
Direction |
M 560-50 K |
Re (MPa) |
T |
380 - 440 |
Rm (MPa) |
T |
435 - 495 |
A80 (%) |
T |
10 - 29 |
HV |
T |
130 - 185 |
M 660-50 K
|
Direction |
M 660-50 K |
Re (MPa) |
T |
350 - 450 |
Rm (MPa) |
T |
380 - 470 |
A80 (%) |
T |
13 - 30 |
HV |
T |
125 - 170 |
M 890-50 K
|
Direction |
M 890-50 K |
Re (MPa) |
T |
285 - 450 |
Rm (MPa) |
T |
350 - 470 |
A80 (%) |
T |
16 - 35 |
HV |
T |
120 - 170 |
M 1050-50 K
|
Direction |
M 1050-50 K |
Re (MPa) |
T |
240 - 450 |
Rm (MPa) |
T |
295 - 470 |
A80 (%) |
T |
21 - 39 |
HV |
T |
105 - 170 |
Prev grade
Next grade
Thickness 0.65 mm
Full table
|
Direction |
Re (MPa) |
Rm (MPa) |
A80 (%) |
HV |
M 390-65 K |
T |
505 - 565 |
560 - 610 |
10 - 21 |
185 - 235 |
M 450-65 K |
T |
435 - 465 |
470 - 510 |
18 - 24 |
180 - 210 |
M 520-65 K |
T |
370 - 440 |
420 - 480 |
12 - 26 |
150 - 190 |
M 630-65 K |
T |
370 - 440 |
420 - 480 |
12 - 31 |
150 - 190 |
M 800-65 K |
T |
360 - 450 |
380 - 470 |
12 - 31 |
130 - 175 |
M 1000-65 K |
T |
280 - 450 |
350 - 470 |
17 - 37 |
120 - 170 |
M 1200-65 K |
T |
270 - 450 |
320 - 470 |
19 - 39 |
100 - 170 |
M 390-65 K
|
Direction |
M 390-65 K |
Re (MPa) |
T |
505 - 565 |
Rm (MPa) |
T |
560 - 610 |
A80 (%) |
T |
10 - 21 |
HV |
T |
185 - 235 |
M 450-65 K
|
Direction |
M 450-65 K |
Re (MPa) |
T |
435 - 465 |
Rm (MPa) |
T |
470 - 510 |
A80 (%) |
T |
18 - 24 |
HV |
T |
180 - 210 |
M 520-65 K
|
Direction |
M 520-65 K |
Re (MPa) |
T |
370 - 440 |
Rm (MPa) |
T |
420 - 480 |
A80 (%) |
T |
12 - 26 |
HV |
T |
150 - 190 |
M 630-65 K
|
Direction |
M 630-65 K |
Re (MPa) |
T |
370 - 440 |
Rm (MPa) |
T |
420 - 480 |
A80 (%) |
T |
12 - 31 |
HV |
T |
150 - 190 |
M 800-65 K
|
Direction |
M 800-65 K |
Re (MPa) |
T |
360 - 450 |
Rm (MPa) |
T |
380 - 470 |
A80 (%) |
T |
12 - 31 |
HV |
T |
130 - 175 |
M 1000-65 K
|
Direction |
M 1000-65 K |
Re (MPa) |
T |
280 - 450 |
Rm (MPa) |
T |
350 - 470 |
A80 (%) |
T |
17 - 37 |
HV |
T |
120 - 170 |
M 1200-65 K
|
Direction |
M 1200-65 K |
Re (MPa) |
T |
270 - 450 |
Rm (MPa) |
T |
320 - 470 |
A80 (%) |
T |
19 - 39 |
HV |
T |
100 - 170 |
Prev grade
Next grade
Thickness 0.70 mm
Full table
|
Direction |
Re (MPa) |
Rm (MPa) |
A80 (%) |
HV |
M 1000-70 K AM FCE |
T |
300 - 340 |
360 - 400 |
28 - 35 |
120 - 140 |
M 1000-70 K AM FCE
|
Direction |
M 1000-70 K AM FCE |
Re (MPa) |
T |
300 - 340 |
Rm (MPa) |
T |
360 - 400 |
A80 (%) |
T |
28 - 35 |
HV |
T |
120 - 140 |
Prev grade
Next grade
Thickness 0.80 mm
Full table
|
Direction |
Re (MPa) |
Rm (MPa) |
A80 (%) |
HV |
M 1200-80 K AM FCE |
T |
320 - 375 |
360 - 400 |
20 - 30 |
125 - 155 |
M 1200-80 K AM FCE
|
Direction |
M 1200-80 K AM FCE |
Re (MPa) |
T |
320 - 375 |
Rm (MPa) |
T |
360 - 400 |
A80 (%) |
T |
20 - 30 |
HV |
T |
125 - 155 |
Prev grade
Next grade
Thickness 1.00 mm
Full table
|
Direction |
Re (MPa) |
Rm (MPa) |
A80 (%) |
HV |
M 1300-100 K AM FCE |
T |
370 - 400 |
390 - 430 |
21 - 27 |
140 - 170 |
M 1800-100 K AM FCE |
T |
255 - 305 |
290 - 335 |
29 - 43 |
105 - 140 |
M 1300-100 K AM FCE
|
Direction |
M 1300-100 K AM FCE |
Re (MPa) |
T |
370 - 400 |
Rm (MPa) |
T |
390 - 430 |
A80 (%) |
T |
21 - 27 |
HV |
T |
140 - 170 |
M 1800-100 K AM FCE
|
Direction |
M 1800-100 K AM FCE |
Re (MPa) |
T |
255 - 305 |
Rm (MPa) |
T |
290 - 335 |
A80 (%) |
T |
29 - 43 |
HV |
T |
105 - 140 |
Prev grade
Next grade
Coating properties
These semi-processed grades are available non-insulated. The final process step in the decarburising annealing treatment carried out by the client provides a suitable atmosphere and thermal conditions for blueing: the formation of an oxide film, which creates the required surface insulation layer.
All details provided in the ArcelorMittal Flat Carbon Europe S.A. catalogue are for information purposes only. ArcelorMittal Flat Carbon Europe S.A. reserves the right to change its product range at any time without prior notice.
For more information on our products, visit the document centre.