When used uncoated and exposed to bad weather, a protective oxide layer develops on the steel surface. That is why this steel is often called “the weathering steel”.
ArcelorMittal's steels with improved atmospheric corrosion resistance are in compliance with the EN 10025-5:2004 standard. These grades are fine-grain, high-strength structural steels offering high yield strength and improved corrosion resistance in specific aggressive environments.
Indaten® 355H meets the requirements of the reference standard and has been further optimised to give extremely high processing and in-service performance.
When used uncoated and exposed to bad weather, an oxide layer develops on the steel surface, forming a purplish-brown, finely grained patina that bonds very strongly to the steel and protects it. With their characteristic colour, steels with improved atmospheric corrosion resistance are used in architectural projects either to harmonise with the environment or to create a pleasing contrast with other materials, such as stainless steel. If the patina is damaged, the steel re-oxidises, thus repairing the patina and maintaining the protective barrier.
Steels with improved atmospheric corrosion resistance can also be coated (paint, metallic coatings etc).
Experience has shown that organic coatings adhere better to these steels than to other steel grades.
Steels with improved atmospheric corrosion resistance have a wide range of applications: architecture, smokestacks, freight wagons, silos, pylons and bridges.
Since 1 July 2013, the Construction Products Regulation (Regulation (EU) No. 305/2011 – CPR) has required that CE marking be affixed to all products delivered in accordance with a harmonised standard (e.g. EN 10025). This CE marking guarantees, for the uses defined in the standard, the properties described in the declaration of performance submitted by the manufacturer.
All of the steels in this data sheet comply with this Regulation.
The corresponding declarations of performance are available on our website at:
http://dop.arcelormittal.net/index.php
The efficiency of the corrosion protection largely depends on the speed of patina formation.
For optimum patina formation:
Steels with improved atmospheric corrosion resistance have excellent weldability with all the usual welding processes because of their low carbon content and fine-grained structure.
Attractive appearance of the patina
Outdoor use: the patina forms naturally in the open air (over a period of three to four years). Variations in appearance will be observed, depending on the conditions it is exposed to: condensation, evacuation and evaporation of water. After a few years, the patina will stabilise, even in an industrial, sulphur-containing or rural environment. To ensure optimum patina formation, the oxidation process can be accelerated artificially by first descaling the surface (by sandblasting or shotblasting) and then subjecting it to alternate periods of dry and humid conditions.
Indoor use: to preserve the natural appearance of the material and at the same time avoid powdery oxide deposits that may cause staining, the following three steps are recommended:
Use painted: as the surface has a high reactivity, it is recommended that the first coat of paint be applied on a clean surface immediately after shotblasting or sandblasting.
Options available (after prior agreement):
EN 10155:1993 | NFA 35 502:1984 | UNE 36082:1984 | DIN 17119:1984 | EN 10025-5:2004 | BS 4360:1990 | Old brand names | |
---|---|---|---|---|---|---|---|
S235J0W EN 10025-5 | S235J0W | E 24 W 3 | AE 235 WC | S235J0W | |||
S235J2W EN 10025-5 | S235J2W | E 24 W 4 | AE 235 WD | W St 37-3 | S235J2W | ||
S355J0WP EN 10025-5 | S355J0WP | E 36 W A 3 | AE 355 W1C | S355J0WP | WR 50A | ||
S355J2WP EN 10025-5 | S355J2WP | E 36 W A 4 | AE 355 W1D | S355J2WP | |||
S355J0W EN 10025-5 | S355J0W | E 36 W B 3 | AE 355 W2C | S355J0W | WR 50B | ||
S355J2W EN 10025-5 | S355J2G2W | E 36 W B 4 | AE 355 W2D | W St 52-3 | S355J2W | WR 50C | |
S355J2W+N EN 10025-5 | S355J2G1W | E 36 W B 4 | AE 355 W2D | S355J2W+N | |||
S355K2W EN 10025-5 | S355K2G2W | S355K2W | |||||
S355K2W+N EN 10025-5 | S355K2G1W | S355K2W+N |
S235J0W EN 10025-5 | |
---|---|
EN 10155:1993 | S235J0W |
NFA 35 502:1984 | E 24 W 3 |
UNE 36082:1984 | AE 235 WC |
DIN 17119:1984 | |
EN 10025-5:2004 | S235J0W |
BS 4360:1990 | |
Old brand names | |
S235J2W EN 10025-5 | |
---|---|
EN 10155:1993 | S235J2W |
NFA 35 502:1984 | E 24 W 4 |
UNE 36082:1984 | AE 235 WD |
DIN 17119:1984 | W St 37-3 |
EN 10025-5:2004 | S235J2W |
BS 4360:1990 | |
Old brand names | |
S355J0WP EN 10025-5 | |
---|---|
EN 10155:1993 | S355J0WP |
NFA 35 502:1984 | E 36 W A 3 |
UNE 36082:1984 | AE 355 W1C |
DIN 17119:1984 | |
EN 10025-5:2004 | S355J0WP |
BS 4360:1990 | WR 50A |
Old brand names | |
S355J2WP EN 10025-5 | |
---|---|
EN 10155:1993 | S355J2WP |
NFA 35 502:1984 | E 36 W A 4 |
UNE 36082:1984 | AE 355 W1D |
DIN 17119:1984 | |
EN 10025-5:2004 | S355J2WP |
BS 4360:1990 | |
Old brand names | |
S355J0W EN 10025-5 | |
---|---|
EN 10155:1993 | S355J0W |
NFA 35 502:1984 | E 36 W B 3 |
UNE 36082:1984 | AE 355 W2C |
DIN 17119:1984 | |
EN 10025-5:2004 | S355J0W |
BS 4360:1990 | WR 50B |
Old brand names | |
S355J2W EN 10025-5 | |
---|---|
EN 10155:1993 | S355J2G2W |
NFA 35 502:1984 | E 36 W B 4 |
UNE 36082:1984 | AE 355 W2D |
DIN 17119:1984 | W St 52-3 |
EN 10025-5:2004 | S355J2W |
BS 4360:1990 | WR 50C |
Old brand names | |
S355J2W+N EN 10025-5 | |
---|---|
EN 10155:1993 | S355J2G1W |
NFA 35 502:1984 | E 36 W B 4 |
UNE 36082:1984 | AE 355 W2D |
DIN 17119:1984 | |
EN 10025-5:2004 | S355J2W+N |
BS 4360:1990 | |
Old brand names | |
S355K2W EN 10025-5 | |
---|---|
EN 10155:1993 | S355K2G2W |
NFA 35 502:1984 | |
UNE 36082:1984 | |
DIN 17119:1984 | |
EN 10025-5:2004 | S355K2W |
BS 4360:1990 | |
Old brand names | |
S355K2W+N EN 10025-5 | |
---|---|
EN 10155:1993 | S355K2G1W |
NFA 35 502:1984 | |
UNE 36082:1984 | |
DIN 17119:1984 | |
EN 10025-5:2004 | S355K2W+N |
BS 4360:1990 | |
Old brand names | |
EN 10155:1993 | NFA 35 502:1984 | UNE 36082:1984 | DIN 17119:1984 | EN 10025-5:2004 | BS 4360:1990 | Old brand names | |
---|---|---|---|---|---|---|---|
Indaten® 355HA | S355J0WP | S355J0WP | Ensacor® A | ||||
Indaten® 355HD | S355J2G1W/S355J2G2W | S355J2W+N/S355J2W | Ensacor® D |
Grades in italics: not included in the standard
Indaten® 355HA | |
---|---|
EN 10155:1993 | S355J0WP |
NFA 35 502:1984 | |
UNE 36082:1984 | |
DIN 17119:1984 | |
EN 10025-5:2004 | S355J0WP |
BS 4360:1990 | |
Old brand names | Ensacor® A |
Grades in italics: not included in the standard
Indaten® 355HD | |
---|---|
EN 10155:1993 | S355J2G1W/S355J2G2W |
NFA 35 502:1984 | |
UNE 36082:1984 | |
DIN 17119:1984 | |
EN 10025-5:2004 | S355J2W+N/S355J2W |
BS 4360:1990 | |
Old brand names | Ensacor® D |
Grades in italics: not included in the standard
Grades in italics: not included in the standard
For the dimensions available, see Table A in data sheet H99.
S235 grades are feasible for thicknesses up to 100 mm in normalised delivery condition, after prior agreement.
S355W grades are feasible for thicknesses up to 100 mm in normalised delivery condition.
S355WP grades are only feasible for thicknesses up to 12 mm in normalised delivery condition.
Direction | Thickness (mm) | Re (MPa) | Rm (MPa) | A 5.65√So (%) | KV 0°C (J) | KV -20°C (J) | |
---|---|---|---|---|---|---|---|
S235J0W EN 10025-5 | L | 5 - 40 | - | - | ≥ 26 | ≥ 27 | - |
40 - 63 | ≥ 25 | ||||||
63 - 100 | ≥ 24 | ||||||
T | 5 - 16 | ≥ 235 | 360 - 510 | ≥ 24 | - | - | |
16 - 40 | ≥ 225 | ||||||
40 - 63 | ≥ 215 | ≥ 23 | |||||
63 - 100 | ≥ 22 | ||||||
S235J2W EN 10025-5 | L | 5 - 40 | - | - | ≥ 26 | - | ≥ 27 |
40 - 63 | ≥ 25 | ||||||
63 - 100 | ≥ 24 | ||||||
T | 5 - 16 | ≥ 235 | 360 - 510 | ≥ 24 | - | - | |
16 - 40 | ≥ 225 | ||||||
40 - 63 | ≥ 215 | ≥ 23 | |||||
63 - 100 | ≥ 22 | ||||||
S355J0WP EN 10025-5 | L | 5 - 12 | - | - | ≥ 22 | ≥ 27 | - |
T | 5 - 12 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
S355J2WP EN 10025-5 | L | 5 - 12 | - | - | ≥ 22 | - | ≥ 27 |
T | 5 - 12 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
S355J0W EN 10025-5 | L | 5 - 40 | - | - | ≥ 22 | ≥ 27 | - |
40 - 63 | ≥ 21 | ||||||
63 - 100 | ≥ 20 | ||||||
T | 5 - 16 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
16 - 40 | ≥ 345 | ||||||
40 - 63 | ≥ 335 | ≥ 19 | |||||
63 - 80 | ≥ 325 | ≥ 18 | |||||
80 - 100 | ≥ 315 | ||||||
S355J2W EN 10025-5 | L | 5 - 40 | - | - | ≥ 22 | - | ≥ 27 |
40 - 63 | ≥ 21 | ||||||
63 - 100 | ≥ 20 | ||||||
T | 5 - 16 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
16 - 40 | ≥ 345 | ||||||
40 - 63 | ≥ 335 | ≥ 19 | |||||
63 - 80 | ≥ 325 | ≥ 18 | |||||
80 - 100 | ≥ 315 | ||||||
S355J2W+N EN 10025-5 | L | 5 - 40 | - | - | ≥ 22 | - | ≥ 27 |
40 - 63 | ≥ 21 | ||||||
63 - 100 | ≥ 20 | ||||||
T | 5 - 16 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
16 - 40 | ≥ 345 | ||||||
40 - 63 | ≥ 335 | ≥ 19 | |||||
63 - 80 | ≥ 325 | ≥ 18 | |||||
80 - 100 | ≥ 315 | ||||||
S355K2W EN 10025-5 | L | 5 - 40 | - | - | ≥ 22 | - | ≥ 40 |
40 - 63 | ≥ 21 | ||||||
63 - 80 | ≥ 20 | ||||||
T | 5 - 16 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
16 - 40 | ≥ 345 | ||||||
40 - 63 | ≥ 335 | ≥ 19 | |||||
63 - 80 | ≥ 325 | ≥ 18 | |||||
S355K2W+N EN 10025-5 | L | 5 - 40 | - | - | ≥ 22 | - | ≥ 40 |
40 - 63 | ≥ 21 | ||||||
63 - 100 | ≥ 20 | ||||||
T | 5 - 16 | ≥ 355 | 470 - 630 | ≥ 20 | - | - | |
16 - 40 | ≥ 345 | ||||||
40 - 63 | ≥ 335 | ≥ 19 | |||||
63 - 80 | ≥ 325 | ≥ 18 | |||||
80 - 100 | ≥ 315 |
Direction | Thickness (mm) | S235J0W EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 235 |
16 - 40 | ≥ 225 | ||
40 - 100 | ≥ 215 | ||
Rm (MPa) | T | 5 - 100 | 360 - 510 |
A 5.65√So (%) | L | 5 - 40 | ≥ 26 |
40 - 63 | ≥ 25 | ||
63 - 100 | ≥ 24 | ||
T | 5 - 40 | ≥ 24 | |
40 - 63 | ≥ 23 | ||
63 - 100 | ≥ 22 | ||
KV 0°C (J) | L | 5 - 100 | ≥ 27 |
Direction | Thickness (mm) | S235J2W EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 235 |
16 - 40 | ≥ 225 | ||
40 - 100 | ≥ 215 | ||
Rm (MPa) | T | 5 - 100 | 360 - 510 |
A 5.65√So (%) | L | 5 - 40 | ≥ 26 |
40 - 63 | ≥ 25 | ||
63 - 100 | ≥ 24 | ||
T | 5 - 40 | ≥ 24 | |
40 - 63 | ≥ 23 | ||
63 - 100 | ≥ 22 | ||
KV -20°C (J) | L | 5 - 100 | ≥ 27 |
Direction | Thickness (mm) | S355J0WP EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 12 | ≥ 355 |
Rm (MPa) | T | 5 - 12 | 470 - 630 |
A 5.65√So (%) | L | 5 - 12 | ≥ 22 |
T | 5 - 12 | ≥ 20 | |
KV 0°C (J) | L | 5 - 12 | ≥ 27 |
Direction | Thickness (mm) | S355J2WP EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 12 | ≥ 355 |
Rm (MPa) | T | 5 - 12 | 470 - 630 |
A 5.65√So (%) | L | 5 - 12 | ≥ 22 |
T | 5 - 12 | ≥ 20 | |
KV -20°C (J) | L | 5 - 12 | ≥ 27 |
Direction | Thickness (mm) | S355J0W EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 355 |
16 - 40 | ≥ 345 | ||
40 - 63 | ≥ 335 | ||
63 - 80 | ≥ 325 | ||
80 - 100 | ≥ 315 | ||
Rm (MPa) | T | 5 - 100 | 470 - 630 |
A 5.65√So (%) | L | 5 - 40 | ≥ 22 |
40 - 63 | ≥ 21 | ||
63 - 100 | ≥ 20 | ||
T | 5 - 40 | ≥ 20 | |
40 - 63 | ≥ 19 | ||
63 - 100 | ≥ 18 | ||
KV 0°C (J) | L | 5 - 100 | ≥ 27 |
Direction | Thickness (mm) | S355J2W EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 355 |
16 - 40 | ≥ 345 | ||
40 - 63 | ≥ 335 | ||
63 - 80 | ≥ 325 | ||
80 - 100 | ≥ 315 | ||
Rm (MPa) | T | 5 - 100 | 470 - 630 |
A 5.65√So (%) | L | 5 - 40 | ≥ 22 |
40 - 63 | ≥ 21 | ||
63 - 100 | ≥ 20 | ||
T | 5 - 40 | ≥ 20 | |
40 - 63 | ≥ 19 | ||
63 - 100 | ≥ 18 | ||
KV -20°C (J) | L | 5 - 100 | ≥ 27 |
Direction | Thickness (mm) | S355J2W+N EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 355 |
16 - 40 | ≥ 345 | ||
40 - 63 | ≥ 335 | ||
63 - 80 | ≥ 325 | ||
80 - 100 | ≥ 315 | ||
Rm (MPa) | T | 5 - 100 | 470 - 630 |
A 5.65√So (%) | L | 5 - 40 | ≥ 22 |
40 - 63 | ≥ 21 | ||
63 - 100 | ≥ 20 | ||
T | 5 - 40 | ≥ 20 | |
40 - 63 | ≥ 19 | ||
63 - 100 | ≥ 18 | ||
KV -20°C (J) | L | 5 - 100 | ≥ 27 |
Direction | Thickness (mm) | S355K2W EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 355 |
16 - 40 | ≥ 345 | ||
40 - 63 | ≥ 335 | ||
63 - 80 | ≥ 325 | ||
Rm (MPa) | T | 5 - 80 | 470 - 630 |
A 5.65√So (%) | L | 5 - 40 | ≥ 22 |
40 - 63 | ≥ 21 | ||
63 - 80 | ≥ 20 | ||
T | 5 - 40 | ≥ 20 | |
40 - 63 | ≥ 19 | ||
63 - 80 | ≥ 18 | ||
KV -20°C (J) | L | 5 - 80 | ≥ 40 |
Direction | Thickness (mm) | S355K2W+N EN 10025-5 | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 355 |
16 - 40 | ≥ 345 | ||
40 - 63 | ≥ 335 | ||
63 - 80 | ≥ 325 | ||
80 - 100 | ≥ 315 | ||
Rm (MPa) | T | 5 - 100 | 470 - 630 |
A 5.65√So (%) | L | 5 - 40 | ≥ 22 |
40 - 63 | ≥ 21 | ||
63 - 100 | ≥ 20 | ||
T | 5 - 40 | ≥ 20 | |
40 - 63 | ≥ 19 | ||
63 - 100 | ≥ 18 | ||
KV -20°C (J) | L | 5 - 100 | ≥ 40 |
Direction | Thickness (mm) | Re (MPa) | Rm (MPa) | A 5.65√So (%) | KV 0°C (J) | KV -20°C (J) | |
---|---|---|---|---|---|---|---|
Indaten® 355HA | L | 5 - 12 | - | - | ≥ 22 | ≥ 27 | - |
T | 5 - 12 | ≥ 355 | 490 - 630 | ≥ 20 | - | - | |
Indaten® 355HD | L | 5 - 80 | - | - | ≥ 22 | - | ≥ 40 |
T | 5 - 16 | ≥ 355 | 490 - 630 | ≥ 20 | - | - | |
16 - 40 | ≥ 345 | ||||||
40 - 63 | ≥ 335 | ||||||
63 - 80 | ≥ 325 |
Grades in italics: not included in the standard
Direction | Thickness (mm) | Indaten® 355HA | |
---|---|---|---|
Re (MPa) | T | 5 - 12 | ≥ 355 |
Rm (MPa) | T | 5 - 12 | 490 - 630 |
A 5.65√So (%) | L | 5 - 12 | ≥ 22 |
T | 5 - 12 | ≥ 20 | |
KV 0°C (J) | L | 5 - 12 | ≥ 27 |
Grades in italics: not included in the standard
Direction | Thickness (mm) | Indaten® 355HD | |
---|---|---|---|
Re (MPa) | T | 5 - 16 | ≥ 355 |
16 - 40 | ≥ 345 | ||
40 - 63 | ≥ 335 | ||
63 - 80 | ≥ 325 | ||
Rm (MPa) | T | 5 - 80 | 490 - 630 |
A 5.65√So (%) | L | 5 - 80 | ≥ 22 |
T | 5 - 80 | ≥ 20 | |
KV -20°C (J) | L | 5 - 80 | ≥ 40 |
Grades in italics: not included in the standard
Grades in italics: not included in the standard
Notes | C (%) | Mn (%) | P (%) | S (%) | Si (%) | Cu (%) | Cr (%) | Ni (%) | N (%) | Mo (%) | |
---|---|---|---|---|---|---|---|---|---|---|---|
S235J0W EN 10025-5 | ≤ 0.13 | 0.20 - 0.60 | ≤ 0.035 | ≤ 0.035 | ≤ 0.40 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | ≤ 0.009 | - | |
S235J2W EN 10025-5 | ≤ 0.13 | 0.20 - 0.60 | ≤ 0.035 | ≤ 0.030 | ≤ 0.40 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | - | - | |
S355J0WP EN 10025-5 | ≤ 0.12 | ≤ 1.00 | 0.060 - 0.150 | ≤ 0.035 | ≤ 0.75 | 0.25 - 0.55 | 0.30 - 1.25 | ≤ 0.65 | ≤ 0.009 | - | |
S355J2WP EN 10025-5 | ≤ 0.12 | ≤ 1.00 | 0.060 - 0.150 | ≤ 0.030 | ≤ 0.75 | 0.25 - 0.55 | 0.30 - 1.25 | ≤ 0.65 | - | - | |
S355J0W EN 10025-5 | 1 | ≤ 0.16 | 0.50 - 1.50 | ≤ 0.035 | ≤ 0.035 | ≤ 0.50 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | ≤ 0.009 | ≤ 0.30 |
S355J2W EN 10025-5 | 1 | ≤ 0.16 | 0.50 - 1.50 | ≤ 0.030 | ≤ 0.030 | ≤ 0.50 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | - | ≤ 0.30 |
S355J2W+N EN 10025-5 | 1 | ≤ 0.16 | 0.50 - 1.50 | ≤ 0.030 | ≤ 0.030 | ≤ 0.50 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | - | ≤ 0.30 |
S355K2W EN 10025-5 | 1 | ≤ 0.16 | 0.50 - 1.50 | ≤ 0.030 | ≤ 0.030 | ≤ 0.50 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | - | ≤ 0.30 |
S355K2W+N EN 10025-5 | 1 | ≤ 0.16 | 0.50 - 1.50 | ≤ 0.030 | ≤ 0.030 | ≤ 0.50 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | - | ≤ 0.30 |
1. Zr ≤ 0.15%
Notes | ||
---|---|---|
C (%) | ≤ 0.13 | |
Mn (%) | 0.20 - 0.60 | |
P (%) | ≤ 0.035 | |
S (%) | ≤ 0.035 | |
Si (%) | ≤ 0.40 | |
Cu (%) | 0.25 - 0.55 | |
Cr (%) | 0.40 - 0.80 | |
Ni (%) | ≤ 0.65 | |
N (%) | ≤ 0.009 |
Notes | ||
---|---|---|
C (%) | ≤ 0.13 | |
Mn (%) | 0.20 - 0.60 | |
P (%) | ≤ 0.035 | |
S (%) | ≤ 0.030 | |
Si (%) | ≤ 0.40 | |
Cu (%) | 0.25 - 0.55 | |
Cr (%) | 0.40 - 0.80 | |
Ni (%) | ≤ 0.65 |
Notes | ||
---|---|---|
C (%) | ≤ 0.12 | |
Mn (%) | ≤ 1.00 | |
P (%) | 0.060 - 0.150 | |
S (%) | ≤ 0.035 | |
Si (%) | ≤ 0.75 | |
Cu (%) | 0.25 - 0.55 | |
Cr (%) | 0.30 - 1.25 | |
Ni (%) | ≤ 0.65 | |
N (%) | ≤ 0.009 |
Notes | ||
---|---|---|
C (%) | ≤ 0.12 | |
Mn (%) | ≤ 1.00 | |
P (%) | 0.060 - 0.150 | |
S (%) | ≤ 0.030 | |
Si (%) | ≤ 0.75 | |
Cu (%) | 0.25 - 0.55 | |
Cr (%) | 0.30 - 1.25 | |
Ni (%) | ≤ 0.65 |
Notes | ||
---|---|---|
C (%) | 1 | ≤ 0.16 |
Mn (%) | 1 | 0.50 - 1.50 |
P (%) | 1 | ≤ 0.035 |
S (%) | 1 | ≤ 0.035 |
Si (%) | 1 | ≤ 0.50 |
Cu (%) | 1 | 0.25 - 0.55 |
Cr (%) | 1 | 0.40 - 0.80 |
Ni (%) | 1 | ≤ 0.65 |
N (%) | 1 | ≤ 0.009 |
Mo (%) | 1 | ≤ 0.30 |
1. Zr ≤ 0.15%
Notes | ||
---|---|---|
C (%) | 1 | ≤ 0.16 |
Mn (%) | 1 | 0.50 - 1.50 |
P (%) | 1 | ≤ 0.030 |
S (%) | 1 | ≤ 0.030 |
Si (%) | 1 | ≤ 0.50 |
Cu (%) | 1 | 0.25 - 0.55 |
Cr (%) | 1 | 0.40 - 0.80 |
Ni (%) | 1 | ≤ 0.65 |
Mo (%) | 1 | ≤ 0.30 |
1. Zr ≤ 0.15%
Notes | ||
---|---|---|
C (%) | 1 | ≤ 0.16 |
Mn (%) | 1 | 0.50 - 1.50 |
P (%) | 1 | ≤ 0.030 |
S (%) | 1 | ≤ 0.030 |
Si (%) | 1 | ≤ 0.50 |
Cu (%) | 1 | 0.25 - 0.55 |
Cr (%) | 1 | 0.40 - 0.80 |
Ni (%) | 1 | ≤ 0.65 |
Mo (%) | 1 | ≤ 0.30 |
1. Zr ≤ 0.15%
Notes | ||
---|---|---|
C (%) | 1 | ≤ 0.16 |
Mn (%) | 1 | 0.50 - 1.50 |
P (%) | 1 | ≤ 0.030 |
S (%) | 1 | ≤ 0.030 |
Si (%) | 1 | ≤ 0.50 |
Cu (%) | 1 | 0.25 - 0.55 |
Cr (%) | 1 | 0.40 - 0.80 |
Ni (%) | 1 | ≤ 0.65 |
Mo (%) | 1 | ≤ 0.30 |
1. Zr ≤ 0.15%
Notes | ||
---|---|---|
C (%) | 1 | ≤ 0.16 |
Mn (%) | 1 | 0.50 - 1.50 |
P (%) | 1 | ≤ 0.030 |
S (%) | 1 | ≤ 0.030 |
Si (%) | 1 | ≤ 0.50 |
Cu (%) | 1 | 0.25 - 0.55 |
Cr (%) | 1 | 0.40 - 0.80 |
Ni (%) | 1 | ≤ 0.65 |
Mo (%) | 1 | ≤ 0.30 |
1. Zr ≤ 0.15%
1. Zr ≤ 0.15%
Notes | C (%) | Mn (%) | P (%) | S (%) | Si (%) | Al (%) | Cu (%) | Cr (%) | Ni (%) | Nb (%) | V (%) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Indaten® 355HA | ≤ 0.12 | ≤ 1.00 | 0.060 - 0.150 | ≤ 0.040 | ≤ 0.75 | ≥ 0.020 | 0.25 - 0.55 | 0.30 - 1.25 | ≤ 0.65 | 0.015 - 0.060 | 0.02 - 0.25 | |
Indaten® 355HD | 1 | ≤ 0.16 | 0.75 - 1.50 | ≤ 0.025 | ≤ 0.025 | ≤ 0.50 | ≥ 0.020 | 0.25 - 0.55 | 0.40 - 0.80 | ≤ 0.65 | 0.015 - 0.060 | 0.02 - 0.25 |
Grades in italics: not included in the standard
1. Zr ≤ 0.15%
Notes | ||
---|---|---|
C (%) | ≤ 0.12 | |
Mn (%) | ≤ 1.00 | |
P (%) | 0.060 - 0.150 | |
S (%) | ≤ 0.040 | |
Si (%) | ≤ 0.75 | |
Al (%) | ≥ 0.020 | |
Cu (%) | 0.25 - 0.55 | |
Cr (%) | 0.30 - 1.25 | |
Ni (%) | ≤ 0.65 | |
Nb (%) | 0.015 - 0.060 | |
V (%) | 0.02 - 0.25 |
Grades in italics: not included in the standard
Notes | ||
---|---|---|
C (%) | 1 | ≤ 0.16 |
Mn (%) | 1 | 0.75 - 1.50 |
P (%) | 1 | ≤ 0.025 |
S (%) | 1 | ≤ 0.025 |
Si (%) | 1 | ≤ 0.50 |
Al (%) | 1 | ≥ 0.020 |
Cu (%) | 1 | 0.25 - 0.55 |
Cr (%) | 1 | 0.40 - 0.80 |
Ni (%) | 1 | ≤ 0.65 |
Nb (%) | 1 | 0.015 - 0.060 |
V (%) | 1 | 0.02 - 0.25 |
Grades in italics: not included in the standard
1. Zr ≤ 0.15%
Grades in italics: not included in the standard
1. Zr ≤ 0.15%
Any questions?
Ask them via our contact form on
https://industry.arcelormittal.com/getintouch
All details provided in the ArcelorMittal Flat Carbon Europe S.A. catalogue are for information purposes only. ArcelorMittal Flat Carbon Europe S.A. reserves the right to change its product range at any time without prior notice.